エンジニアリング計算機
Capacitor Energy and Peak Current Calculator
図の読み方。 Closing the switch dumps the stored charge through the load resistor. Peak current is set by V / R at the instant of closure and then decays as e−t/RC, which is the pulse drawn on the right.
Stored energy decides whether a pulse is safe and whether the capacitor survives it. Enter capacitance, voltage and the discharge resistance to get energy, charge and peak current.
入力
結果
- 蓄積エネルギー
- -
- 料金
- -
- ピーク電流
- -
- 時定数
- -
式
E = ½ × C × V². Charge Q = C × V. Peak discharge current I = V / R at the instant the circuit closes, decaying with τ = R × C.
電卓に含まれていないもの
- 脈拍持続時間。 Peak current lasts microseconds in a low-resistance loop. The capacitor must be rated for that dV/dt, not only for the energy.
- 繰り返し。 A pulse that is safe once can overheat at 100 Hz. Ask for pulse data on the specific part.
- Dielectric absorption. After discharge the capacitor recovers part of its voltage, which is why bleeder design matters.
パーツの選択
Pulse and PFN duty usually calls for N4700 Class 1 in a 放射状円盤 または screw-terminal doorknob. Class 2 drift makes those parts a poor fit for repeated pulses.
計算値と税率を送信してください。 技術見積もりを依頼する6時間以内に返信いたします。